Heller Model 1500S |
|
|
Mesh Belt Conveyor |
|
|
Conveyor Height From Floor |
35"+3/-2" |
|
Maximum PCB Width |
22"(56cm) |
|
Conveyor Length On-Load |
18"(46cm) |
|
Conveyor Length Off-Load |
18"(46cm) |
|
Heated Tunnel Length |
72"(183cm) |
|
Conveyor Direction L to R |
S |
|
Conveyor Direction R to L |
O |
|
Maximum Conveyor Speed |
76"(193cm)/min |
|
Conveyor Speed Control |
Closed Loop |
|
Process Clearance Above Mesh Belt |
2.3"(5.8cm) |
|
Edge Hold Conveyor |
|
|
Power Width Adjustment |
S |
|
Computer Width Adjustment |
O |
|
Clearance Above Conveyor Pins |
1.2"(3cm) |
|
Clearance Below Conveyor Pins |
1.2"(3cm) |
|
Length of Board Support Pin |
0.15"(3.8cm) |
|
Minimum/Maximum Board Width |
2.21"(5-53cm) |
|
Forced Convection Zones |
|
|
Top |
5 |
|
Bottom |
5 |
|
Heater Type |
Instant response open coil |
|
Warns-Up Time From Cold Start |
15 minutes |
|
Profile Change Time |
< 5 Minutes |
|
Temperature Control |
|
|
Accuracy of Temperature |
± 1°C |
|
Cross-Belt Temperature Tolerance |
± 3°C |
|
Heater Wattage Per Zone |
6000w |
|
Temperature Range Standard |
25-300°C |
|
High Temperature Up To 350°C |
O |
|
UV Cure |
O |
|
Cooling System |
|
|
Number of Internal Cooling Zones |
1 |
|
External Cooling Zone |
0 |
|
Water Cooling |
- |
|
Electric Supply |
|
|
Power Input (3 phase) Standard |
208 or 240 volts |
|
Warm Up Current |
100 amps @ 208v |
|
Run Current |
45 amps @ 208v |
|
Optional Inputs Available |
380/400/415/ |
|
Frequency |
50/60/ Hz |
|
Sequential Zone Turn On |
S |
|
Dimensions |
|
|
Overall Length |
134"(340cm) |
|
Overall Width |
36"(91cm) |
|
Overall Height |
54"(137cm) |
|
Net Weight |
2000 lbs. (900kg) |
|
Shipping Weight |
2500 lbs. (1127kg) |
|
Inert Atmosphere |
|
|
Minimum PPM 02 |
- |
|
Flexible Entrance and Exit Doors |
- |
|
N2/Air Valve |
- |
|
02 Monitoring System |
- |
|
N2 Standby System |
- |
|
Sample Ports in Reflow |
- |
|
Typical N2 Consumption @ 25 PPM |
- |
|
S = Standard O = Optional |
|